CAN/CSA N287.7-96 (R2005)
In-Service Examination and Testing Requirements for Concrete Containment Structures for CANDU Nuclear Power Plants
standard by Canadian Standards Association / National Standard of Canada, 01/18/2000
Full Description
1. Scope
1.1
This Standard provides the requirements for in-service examinations and positive pressure leakage rate testing of concrete containment structures of a containment system, designed as Class Containment components during outages. Note: The requirements for periodic testing and inspection of other components and appurtenances of the containment system designed in accordance with the CAN/CSA-N285 Series of Standards are beyond the scope of this Standard. Users are referred to CSA Standard CAN/CSA-N285.5.