M00051819
New product
CSA C22.2 NO. 1993-12 Self-Ballasted Lamps and Lamp Adapters (Tri-national standard, with UL 1993 and NMX-J-578/1-ANCE)
standard by CSA Group, 12/04/2012
In stock
Warning: Last items in stock!
Availability date: 01/10/2022
Legal Notice for Standards
Canadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.
Disclaimer and exclusion of liability
This document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this document’s fitness for a particular purpose or use, its merchantability, or its non-infringement of any third party’s intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this document’s compliance with any applicable statute, rule, or regulation.
IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.
In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document.
CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.
Intellectual property rights and ownership
As between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Group’s and/or others’ intellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.
Patent rights
Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.
Authorized use of this document
This document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:
If this document is in electronic form:
s LOAD THIS DOCUMENT ONTO A COMPUTER FOR THE SOLE PURPOSE OF REVIEWING IT s SEARCH AND BROWSE THIS DOCUMENT AND
s PRINT THIS DOCUMENT IF IT IS IN 0$& FORMAT
Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such copy.
In addition, users may not and may not permit others to
s ALTER THIS DOCUMENT IN ANY WAY OR REMOVE THIS ,EGAL .OTICE FROM THE ATTACHED STANDARD s SELL THIS DOCUMENT WITHOUT AUTHORIZATION FROM #3! 'ROUP OR
s MAKE AN ELECTRONIC COPY OF THIS DOCUMENT
If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.
C22.2 No. 1993-12
December 2012
Title: Self-ballasted lamps and lamp adapters
Pagination: 114 pages, each dated December 2012
To register for e-mail notification about any updates to this publication
go to shop.csa.ca
click on CSA Update Service
The List ID that you will need to register for updates to this publication is 2422441.
If you require assistance, please e-mail techsupport@csagroup.org or call 416-747-2233.
Visit CSA Group’s policy on privacy at csagroup.org/legal to find out how we protect your personal information.
C22.2 No. 1993-12
TMA trade-mark of the Canadian Standards Association, operating as “CSA Group”
Published in December 2012 by CSA Group A not-for-profit private sector organization
5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6 1-800-463-6727 • 416-747-4044
Visit our Online Store at shop.csa.ca
Association of Standardization and Certification NMX-J-578/1-ANCE
Second Edition
CSA Group
CSA C22.2 No. 1993-12
Second Edition
Underwriters Laboratories Inc. UL 1993
Fourth Edition
Self-Ballasted Lamps and Lamp Adapters
December 4, 2012
ANSI/UL 1993-2012
Commitment for Amendments
This standard is issued jointly by the Association of Standardization and Certification (ANCE), the Canadian Standards Association operating as “CSA Group”, and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the procedures may be submitted to ANCE, CSA Group, or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA and UL pages.
Copyright © 2012 ANCE
Rights reserved in favor of ANCE
ISBN 978-1-77139-166-5 © 2012 CSA Group
All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher.
This standard is subject to periodic review, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquiries@csagroup.org and include “Proposal for change” in the subject line: Standard designation (number); relevant clause, table, and/or figure number; wording of the proposed change; and rationale for the change.
To purchase CSA Group Standards and related publications, visit CSA Group’s Online Store at
shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044.
Copyright © 2012 Underwriters Laboratories Inc.
UL’s Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of UL’s Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL.
This ANSI/UL Standard for Safety consists of the Fourth Edition.
The most recent designation of ANSI/UL 1993 as an American National Standard (ANSI) occurred on December 4, 2012. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, Preface, or effective date information.
Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in UL’s On-Line Collaborative Standards Development System (CSDS) at https://csds.ul.com.
To purchase UL Standards, visit Comm 2000 at https://www.comm-2000.com/help/how_to_order.aspx or call toll-free 1-888-853-3503.
NOTE – The user’s attention is called to the possibility that compliance with this standard may require use of an invention covered by patent rights.
By publication of this standard, no position is taken with respect to the validity of this claim or of any patent rights in connection there with. The patent holder has, however, filed a statement of willingness to grant a license under these rights on reasonable and nondiscriminatory terms and conditions to applicants desiring to obtain such a license. Details may be obtained from UL.
4 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 DECEMBER 4, 2012
No Text on This Page
DECEMBER 4, 2012 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 5
CONTENTS
Preface 9
Scope 11
Reference Publications 11
Normative references 11
Informative references 15
Definitions 15
General Requirements 18
Components 18
Application of requirements 19
Units of measurement 19
Assembly and packaging 19
Principles 20
Mechanical Construction 20
Enclosures 20
Openings 21
Polymeric materials 22
Weight and moment 24
Electrical Construction 24
Lamp bases and lampholders 24
Current-carrying parts 25
Printed circuit boards 26
Ballasts and LED drivers 26
Power capacitors 28
Spacing of electrical parts 28
Accessibility of live parts 29
Light source – fluorescent lamps 29
Light source – light emitting diodes (LED) 30
Light source – non-discharge lamps 30
Environmental Locations 30
Dry locations 30
Damp locations 31
Wet locations 31
Tests 31
General 31
Input measurements 33
Lamp starting and operating measurements 34
Leakage-current test 34
Temperature test 34
Dielectric voltage-withstand test 37
Harmonic distortion test 38
Drop impact test 39
Mold-stress relief conditioning 39
Deflection test 40
Strain relief test for lamp connectors 40
Tests of dimmer circuits 40
Humidity conditioning 42
Water spray test 43
Cold impact test 43
Lamp fault conditions test 43
6 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 DECEMBER 4, 2012
End-of-lamp-life tests for fluorescent lamp adapters 45
End-of-life test for integral, self-ballasted fluorescent lamps – one filament emission-mix-free test 55
Test Apparatus 56
General 56
Instrumentation 56
Thermocouples 57
Plywood test box material 57
Temperature test box 57
Articulated probe 62
Water spray apparatus 64
Cheesecloth 67
Device Markings 67
General 67
Identifications and ratings 68
Marking requirements in Mexico 71
Instructions 73
SUPPLEMENT SA - SUPPLEMENTAL REQUIREMENTS FOR LIGHT-EMITTING DIODES (LED)
SA1 Scope 1
SA2 Reference Publications 1
SA3 Definitions 1
SA4 General Requirements 3
SA5 Mechanical Construction 3
SA5.1 Enclosures 3
SA5.2 Openings 3
SA5.3 Polymeric materials 4
SA5.4 Weight and moment 5
SA6 Electrical Construction 5
SA6.1 Lamp bases and lampholders 5
SA6.2 Current-carrying parts 6
SA6.3 Printed circuit boards 6
SA6.4 Ballasts and LED drivers 6
SA6.5 Power capacitors 7
SA6.6 Spacing of electrical parts 7
SA6.7 Accessibility of live parts 7
SA6.8 Light source – fluorescent lamps 7
SA6.9 Light source – light emitting diodes (LED) 7
SA6.10 Light source – non-discharge lamps 8
SA6.11 Grounding 8
SA6.12 Polarization 8
SA6.13 Devices substituting for linear fluorescent lamps 8
SA6.14 Devices interchangeable with tungsten-halogen incandescent lamps 10
SA7 Environmental Locations 10
SA8 Tests 11
SA8.1 General 11
SA8.2 Input measurements 11
SA8.3 Lamp starting and operating measurements 12
SA8.4 Leakage-current test 12
SA8.5 Temperature test 12
DECEMBER 4, 2012 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 7
SA8.6 Dielectric voltage-withstand test 12
SA8.7 Harmonic distortion test 13
SA8.8 Drop impact test 13
SA8.9 Mold-stress relief conditioning 13
SA8.10 Deflection test 13
SA8.11 Strain relief test for lamp connectors 13
SA8.12 Tests of dimmer circuits 14
SA8.13 Humidity conditioning 14
SA8.14 Water spray test 14
SA8.15 Cold impact test 14
SA8.16 Lamp fault conditions test 14
SA8.17 End-of-lamp-life tests for fluorescent lamp adapters 14
SA8.18 End-of-life test for integral, self-ballasted fluorescent lamps - one filament emission-mix-free test 14
SA8.19 Risk of electric shock – relamping 14
SA8.20 Isolation of lamp pins 15
SA8.21 Misapplication of lamp supply connections 16
SA8.22 LED lamp and driver abnormal condition tests 17
SA9 Test Apparatus 17
SA9.1 General 17
SA9.2 Instrumentation 18
SA9.3 Thermocouples 18
SA9.4 Plywood test box material 18
SA9.5 Temperature test boxes 18
SA9.6 Articulated probe 19
SA9.7 Water spray apparatus 19
SA9.8 Cheesecloth 19
SA10 Device Markings 19
SA10.1 General 19
SA10.2 Identifications and ratings 19
SA10.3 Marking requirements in Mexico 21
SA10.4 Instructions 21
ANNEX A (normative) Standards for Components
ANNEX B (CAN) (normative) Markings – French Translations
ANNEX C (MEX) (normative) Markings – Spanish Translations
ANNEX D (normative) Manufacturing and Production Tests
D.1 Dielectric Voltage-Withstand Test 32
8 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 DECEMBER 4, 2012
ANNEX E (CAN) (normative) Printed Circuit Boards
Special Terminology 34
General 34
Printed Circuit Board Coatings 35
Dielectric strength 35
Adhesion 36
ANNEX F (informative) Pictograms
ANNEX G (informative) Metric Conversion Information
DECEMBER 4, 2012 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 9
Preface
This is the harmonized ANCE, CSA Group, and UL Standard for Self-Ballasted Lamps and Lamp Adapters. It is the second edition of NMX-J-578/1-ANCE, the second edition of CSA C22.2 No. 1993, and the fourth edition of UL 1993. This edition of CSA C22.2 No. 1993 replaces the Technical Information Letter TIL No. B-36B “Self-Ballasted Fluorescent Lamps with Medium Screw-Base and Integral-Ballasted Adapters with Medium Screw-Base for Fluorescent Lamps.” This edition of UL 1993 supersedes the previous edition published in 2009.
The end-of-lamp-life tests for fluorescent lamp adapters material is reproduced from IEC 61347-2-3 with permission of the American National Standards Institute (ANSI) on behalf of the International Electrotechnical Commission (IEC). No part of this material may be copied or reproduced in any form, electronic retrieval system or otherwise or made available on the Internet, a public network, by satellite or otherwise without the prior written consent of the American National Standards Institute. Copies of IEC standards may be purchased from the American National Standards Institute, 25 West 43rd Street, New York, NY 10036, (212) 642-4900, https://webstore.ansi.org.
This standard contains information copyright protected by the International Electrotechnical Commission (IEC). The end-of-lamp-life tests for fluorescent lamp adapters material is reproduced from IEC 61347-2-3 with permission from the Standards Council of Canada (SCC) in Canada on behalf of the International Electrotechnical Commission (IEC). Except as permitted under the laws of Canada, no extract of the International Standard may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, electronic, photocopying, recording, or otherwise, without prior permission from the Standards Council of Canada (SCC).
This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), the CSA Group, and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee for Self-Ballasted Lamps, of the Council of the Harmonization of Electrotechnical Standards for the Nations of the Americas (CANENA), are gratefully acknowledged.
This standard is considered suitable for use for conformity assessment within the stated scope of the standard.
This standard was reviewed by the CSA Subcommittee on Lighting Products, under the jurisdiction of the CSA Technical Committee on Consumer and Commercial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee.
In Canada, for general information on the Standards of the Canadian Electrical Code, Part II, see the preface to CAN/CSA-C22.2 No. 0.
This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard.
A UL standard is current only if it incorporates the most recently adopted revisions, all of which are itemized on the transmittal notice that accompanies the latest set of revised requirements.
NOTE Although the intended primary application of this standard is stated in its scope, it is important to note that it remains the responsibility of the users of the standard to judge its suitability for their particular purpose.
10 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 DECEMBER 4, 2012
Level of harmonization
This standard is published as an equivalent standard for CSA Group and UL and a proposed equivalent standard for ANCE. An equivalent standard is a standard that is substantially the same in technical content, except as follows. Technical national differences are allowed for codes and governmental regulations as well as those recognized as being in accordance with NAFTA Article 905, for example, because of fundamental climatic, geographical, technological, or infrastructural factors, scientific justification, or the level of protection that the country considers appropriate. Presentation is word for word except for editorial changes.
Interpretations
The interpretation by the standards development organization of an identical or equivalent standard is based on the literal text to determine compliance with the standard in accordance with the procedural rules of the standards development organization. If more than one interpretation of the literal text has been identified, a revision is to be proposed as soon as possible to each of the standards development organizations to more accurately reflect the intent.
ANCE effective date
The effective date for ANCE will be announced through the Diario Oficial de la Federation (Official Gazette).
CSA Group effective date
The effective date for CSA Group will be announced through CSA Informs or a CSA Group Certification Notice.
UL effective date
As of December 4, 2012, all products Listed or Recognized by UL must comply with the requirements in this standard except for clauses, figures, and tables in the following list, which are effective December 4, 2015.
Clause 6.4.6.
Between December 4, 2012 and December 4, 2015, new product submittals to UL may be evaluated under all requirements in this standard or, if requested in writing, evaluated under presently effective requirements only. The presently effective requirements are contained in the Third Edition of UL 1993.
A UL effective date is one established by Underwriters Laboratories Inc. and is not part of the ANSI approved standard.
DECEMBER 4, 2012 NMX-J-578/1-ANCE CSA C22.2 NO. 1993-12 UL 1993 11
Scope
These requirements are intended to cover both self-ballasted lamps and self-ballasted lamp adapters rated 120 to 347 V AC nominal for connection to screw-base, pin-base, or recessed single contact (RSC or R7) lampholders. These devices are intended for use in accordance with the National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part I, in non-hazardous locations, and the Instalaciones Eléctricas (utilización), NOM-001-SEDE.
These devices incorporate resistance, reactance, or electronic (solid-state) type ballasts or power supplies. These devices employ various lamp technologies including, but not limited to, incandescent, fluorescent, high-intensity discharge lamps, light-emitting diodes.
These requirements also include Supplemental Requirements for Light-Emitting Diodes (LED), Supplement SA, for:
Self-contained LED lamps, rated 120 to 347 V AC nominal for connection to screw-, pin- base, and recessed single contact (RSC or R7) lampholders,
Lamps for replacement of an ANSI standardized fluorescent lamp, and consisting of light- emitting-diode (LED) lamp technologies, with control circuitry, and a driver or power supply. The LED driver and control circuitry will be either integral with the lamp or remote from the lamp, and
Component LED lamps, with or without control circuitry, an ANSI base other than bases mentioned in (a), for connection to LED driver having a low voltage output, such as replacement for tungsten-halogen, MR11 and MR16 shaped lamps.
This standard does not apply to medium-to-medium base (E26) fittings that incorporate controls such as photocells, motion detectors, radio controls, or dimmers covered by other standards.
These devices are not intended for use with emergency exit fixtures or emergency exit lights.
Reference Publications
2.1 Normative references
2.1.1 For undated references to standards, such reference shall be considered to refer to the latest edition and all revisions to that edition up to the time when this standard was approved. For dated references to standards, such reference shall be considered to refer to the dated edition and all revisions published to that edition up to the time the standard was approved.
ANCE (Mexican National Standards)
NMX-J-024-ANCE
Iluminación – Portalámparas roscados tipo Edison – Especificaciones y métodos de prueba
NMX-J-325-ANCE
Iluminación – Portalámparas para lámparas fluorescentes – Especificaciones y métodos de prueba
NMX-J-565/2-11-ANCE
Prueba de riesgo de incendio – Parte 2-10: Métodos de prueba basados en hilo incandescente/caliente
– Método de prueba de inflamabilidad de hilo incandescente para productos finales