M00050238
New product
CSA C22.4 NO. 1:09 (R2018) Objective-based industrial electrical code
standard by CSA Group, 01/01/2009
In stock
Warning: Last items in stock!
Availability date: 01/10/2022
(reaffirmed 2018)
Canadian Standards Association and CSA America, Inc. (operating as “CSA Group”) develop standards through a consensus standards development process approved by the Standards Council of Canada and the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.
Disclaimer and exclusion of liability
This document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this document’s fitness for a particular purpose or use, its merchantability, or its non-infringement of any third party’s intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this document’s compliance with any applicable statute, rule, or regulation.
IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.
In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document.
CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.
Intellectual property rights and ownership
As between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Group’s and/or others’ intellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.
Patent rights
Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.
Authorized use of this document
This document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:
If this document is in electronic form:
load this document onto a computer for the sole purpose of reviewing it;
search and browse this document; and
print this document if it is in PDF format.
Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such copy.
In addition, users may not and may not permit others to
alter this document in any way or remove this Legal Notice from the attached standard;
sell this document without authorization from CSA Group; or
make an electronic copy of this document.
If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.
C22.4 No. 1-09
January 2009
Title: Objective-based industrial electrical code
Pagination: 28 pages (viii preliminary and 20 text), each dated January 2009
To register for e-mail notification about any updates to this publication
go to shop.csa.ca
click on CSA Update Service
The List ID that you will need to register for updates to this publication is 2418903.
If you require assistance, please e-mail techsupport@csagroup.org or call 416-747-2233.
Visit CSA Group’s policy on privacy at csagroup.org/legal to find out how we protect your personal information.
CSA Standard
C22.4 No. 1-09
Objective-based industrial electrical code
Published in January 2009 by Canadian Standards Association A not-for-profit private sector organization
5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6 1-800-463-6727 • 416-747-4044
Visit our Online Store at www.ShopCSA.ca
100%
The Canadian Standards Association (CSA) prints its publications on Rolland Enviro100, which contains 100% recycled post-consumer fibre, is EcoLogo and Processed Chlorine Free certified, and was manufactured using biogas energy.
To purchase CSA Standards and related publications, visit CSA’s Online Store at www.ShopCSA.ca or call toll-free 1-800-463-6727 or 416-747-4044.
ISBN 978-1-55436-800-6
Technical Editor: Michael Wilson
Permission to use extracts from IEC 60364-1:2005 was provided by Standards Council of Canada, in co-operation with IHS Canada. No further reproduction is permitted without prior written approval from Standards Council of Canada.
© Canadian Standards Association — 2009
All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher.
Technical Committee on the Objective-Based Industrial Electrical Code v
Subcommittee on the Objective-Based Industrial Electrical Code — Technical Content vii
Preface viii
0 Object 1
Scope 1
Reference publications 2
Definitions 2
Protection for safety 3
General 3
Protection against electric shock 3
Basic protection (protection against direct contact) 3
Fault protection (protection against indirect contact) 4
Protection against thermal effects 4
Protection against overcurrent 4
Protection against fault currents 4
Protection against voltage disturbances 4
Protection against electromagnetic influences 4
Protection against power supply interruption 5
Design 5
General 5
Characteristics of available supply 5
General 5
Characteristics 5
Nature of demand 6
Electric supply systems for safety services or standby electric supply systems 6
Environmental conditions 6
Cross-section (size) of conductors 6
Type of wiring and methods of installation 7
Protective equipment 7
Emergency control 7
Disconnecting devices 7
Prevention of mutual detrimental influence 7
Accessibility of electrical equipment 7
Run-to-failure 8
General 8
Design 8
Documentation 8
Selection of electrical equipment 8
General 8
Characteristics 8
Compatibility 8
Voltage 9
Current 9
Frequency 9
Load factor 9
Conditions of installation 9
Prevention of harmful effects 9
Erection and verification of electrical installations 9
Erection 9
Verification 10
Operation and maintenance 10
General 10
Operation 10
Maintenance 11
Mothballing and decommissioning 11
Annexes
A (normative) — Electrical equipment selection criteria 12
B (informative) — Technical references 15
Leduc Marex Canada Limited, Calgary, Alberta
Chair
K.L. Rodel Hubbell Canada LP, Pickering, Ontario
Vice-Chair
W.H. Anquetil Schneider Canada Inc., Mississauga, Ontario
Associate
Bygrave Michelin North America (Canada) Inc., New Glasgow, Nova Scotia
J. Dickin Dickin Engineering Inc., Red Deer, Alberta
Associate
S.W. Douglas IAEI,
Cambridge, Ontario
T.S. Driscoll Shell Canada Limited, Calgary, Alberta
T. Flood A.J. Flood and Associates, Burlington, Ontario
Associate
G. Haines Ontario Power Generation, Niagara-on-the-Lake, Ontario
N. Hawkins Ontario Ministry of Labour, Toronto, Ontario
S. Hawkins ShawCor Ltd., Toronto, Ontario
R. Johnson Power Workers’ Union, New Liskeard, Ontario
Associate
R. Lajeunesse Régie du bâtiment du Québec, Montréal, Québec
P. Liberatore Corporation des maîtres électriciens du Québec, Montréal, Québec
P. McDonald Alberta Municipal Affairs, Edmonton, Alberta
L. McGuire Invista (Canada), Kingston, Ontario
Misyk The Inspections Group Inc., Edmonton, Alberta
D.G. Morlidge Fluor Canada Ltd., Calgary, Alberta
J.P. Neu Electro-Federation Canada, Mississauga, Ontario
Olechna Electrical Safety Authority, Mississauga, Ontario
S. Paulsen New Brunswick Department of Public Safety, Fredericton, New Brunswick
K. Powell Criterions,
Glen Williams, Ontario
Associate
V.G. Rowe Westbank, British Columbia Associate
B.A. Savaria Eaton Electrical, Burlington, Ontario
T. Simmons British Columbia Institute of Technology, Burnaby, British Columbia
M. Smith Rockwell Automation Canada Inc., Cambridge, Ontario
Associate
B. Trenholm Petro-Canada,
St. John's, Newfoundland and Labrador
Associate
A. Tsisserev City of Vancouver, Vancouver, British Columbia
M.J. Wilson Canadian Standards Association, Mississauga, Ontario
Project Manager
T.S. Driscoll Shell Canada Limited, Calgary, Alberta
Chair
M. Cole Hubbell Canada LP, Pickering, Ontario
J. Dickin Dickin Engineering Inc., Red Deer, Alberta
T. Flood A.J. Flood and Associates, Burlington, Ontario
G. Haines Ontario Power Generation, Niagara-on-the-Lake, Ontario
R. Leduc Marex Canada Limited, Calgary, Alberta
P. Marcucci Electrical Safety Authority, Mississauga, Ontario
D.G. Morlidge Fluor Canada Ltd., Calgary, Alberta
J.P. Neu Electro-Federation Canada, Mississauga, Ontario
T. Olechna Electrical Safety Authority, Mississauga, Ontario
K. Powell Criterions,
Glen Williams, Ontario
V.G. Rowe Westbank, British Columbia
B.A. Savaria Eaton Electrical, Burlington, Ontario
R. Stromer Imperial Oil Limited, Calgary, Alberta
M.J. Wilson Canadian Standards Association, Mississauga, Ontario
Project Manager
This is the first edition of CSA C22.4 No. 1, Objective-based industrial electrical code.
Permission to use extracts from IEC 60364-1:2005 was provided by Standards Council of Canada, in co-operation with IHS Canada. No further reproduction is permitted without prior written approval from Standards Council of Canada.
This Code was prepared by the Subcommittee on the Objective-Based Industrial Electrical Code — Technical Content, under the jurisdiction of the Technical Committee on the Objective-Based Industrial Electrical Code and the Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee.
Interpretations: The Strategic Steering Committee on Requirements for Electrical Safety has provided the following direction for the interpretation of standards under its jurisdiction: “The literal text shall be used in judging compliance of products with the safety requirements of this Standard. When the literal text cannot be applied to the product, such as for new materials or construction, and when a relevant committee interpretation has not already been published, CSA’s procedures for interpretation shall be followed to determine the intended safety principle”.
January 2009
Notes:
Use of the singular does not exclude the plural (and vice versa) when the sense allows.
Although the intended primary application of this Code is stated in its Scope, it is important to note that it remains the responsibility of the users of the Code to judge its suitability for their particular purpose.
This publication was developed by consensus, which is defined by CSA Policy governing standardization — Code of good practice for standardization as “substantial agreement. Consensus implies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet not be in full agreement with all clauses of this publication.
CSA Standards are subject to periodic review, and suggestions for their improvement will be referred to the appropriate committee.
All enquiries regarding this Code, including requests for interpretation, should be addressed to Canadian Standards Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.
Requests for interpretation should
define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;
provide an explanation of circumstances surrounding the actual field condition; and
be phrased where possible to permit a specific “yes” or “no” answer.
Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and are published in CSA’s periodical Info Update, which is available on the CSA Web site at www.csa.ca.
viii January 2009
C22.4 No. 1-09
This Code is intended for use by an authorized user in conjunction with the implementation of a safety management system developed in accordance with CSA C22.4 No. 2, Objective-based industrial electrical code — Safety management system requirements, and as detailed in the authorized user’s OBIEC safety management manual. This Code provides references to applicable industry-recognized standards, codes, and recommended practices. This Code is intended to apply only to industrial facilities.
This Code is not intended to permit the use or modification of electrical equipment in a manner outside either the application for which the equipment was certified or the written instructions provided by the manufacturer.
1.1
This Code specifies objectives to provide for the safety of persons, livestock, and property against dangers and damage that can arise from the use of electrical installations and to provide for the proper functioning of those installations. In addition, this Code sets objectives for the protection of property against damage, if the damage can lead to unsafe events or conditions for persons and livestock.
1.2
This Code specifies safety objectives for the following criteria in relation to electrical systems operating or intended to operate at all voltages in electrical installations within industrial facilities:
design;
selection of electrical equipment;
erection and verification; and
operation and maintenance.
1.3
This Code specifies technical provisions to address the safety objectives. The technical references in this Code are not exclusive and do not necessarily represent all acceptable solutions that might be considered to have a bearing on the objectives of this Code.
1.4
This Code and any standards referenced herein do not make or imply any assurance or guarantee with respect to the life expectancy, durability, or operating performance of the equipment and material referenced herein.
1.5
In CSA Standards, “shall” is used to express a requirement, i.e., a provision that the authorized user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; “may” is used to express an option or that which is permissible within the limits of the standard; and “can” is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note
January 2009 1