New Reduced price! CSA A123.26:21 View larger

CSA A123.26:21

M00048424

New product

CSA A123.26:21 Performance requirements for climate resilience of low slope membrane roofing systems, Includes Administrative Update (2021)

standard by CSA Group, 01/01/2021

Full Description

Preface:

This is the first edition of CSA A123.26, Performance requirements for climate resilience of low slope membrane roofing systems.

This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.

Scope:

1.1
This Standard outlines requirements for low slope membrane roofing systems (LSMRS) when identified as "silver" and "gold" performance level based on the climate severity and resilience requirements.
Note: The National Building Code of Canada and the National Energy Code of Canada for Buildings provides "bronze" requirements for LSMRS.

1.2
This Standard is intended to be used by building designers, building owners, building code officials, product manufacturers, and installers.

1.3
The requirements provided in this Standard do not include, nor are they intended to override other requirements, by the governing building code or the authority having jurisdiction (AHJ).

1.4
This Standard does not address the climatic adaptation requirements for the structural support (deck) below the LSMRS.

1.5
This Standard does not purport to address all the health and safety aspects associated with its use. Anyone using this Standard has the responsibility to consult with the appropriate authorities and to establish health and safety practices, in conjunction with any existing applicable regulatory requirements, prior to its use.

1.6
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

1.7
The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

More details

In stock

$56.25

-55%

$125.00

More info

CSA A123.26:21, Performance requirements for climate resilience of low slope membrane roofing systems

CSA A123.26:21

National Standard of Canada


Performance requirements for climate resilience of low slope membrane roofing systems


REVISED APRIL 2021

Legal Notice for Standards


Canadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing varied viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.

Disclaimer and exclusion of liability

This document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this document’s fitness for a particular purpose or use, its merchantability, or its non-infringement of any third party’s intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this document’s compliance with any applicable statute, rule, or regulation.

IN NO EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMAGES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.

In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to another person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this document.

CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes.

Intellectual property rights and ownership

As between CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secrets that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Group’s and/or others’ intellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.

Patent rights

Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely their own responsibility.

Authorized use of this document

This document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:

If this document is in electronic form:

  • load this document onto a computer for the sole purpose of reviewing it;

  • search and browse this document; and

  • print this document if it is in PDF format.

    Limited copies of this document in print or paper form may be distributed only to persons who are authorized by CSA Group to have such copies, and only if this Legal Notice appears on each such copy.

    In addition, users may not and may not permit others to

  • alter this document in any way or remove this Legal Notice from the attached standard;

  • sell this document without authorization from CSA Group; or

  • make an electronic copy of this document.

    If you do not agree with any of the terms and conditions contained in this Legal Notice, you may not load or use this document or make any copies of the contents hereof, and if you do make such copies, you are required to destroy them immediately. Use of this document constitutes your acceptance of the terms and conditions of this Legal Notice.


    Revision History

    CSA A123.26:21, Performance requirements for climate resilience of low slope membrane roofing systems


    Administrative update — April 2021

    National Standard of Canada page: French version now available


    Standards Update Service

    CSA A123.26:21

    January 2021


    Title: Performance requirements for climate resilience of low slope membrane roofing systems

    To register for e-mail notification about any updates to this publication

  • go to www.csagroup.org/store/

  • click on Product Updates

The List ID that you will need to register for updates to this publication is 2428698.

If you require assistance, please e-mail techsupport@csagroup.org or call 416-747-2233.

Visit CSA Group’s policy on privacy at www.csagroup.org/legal to find out how we protect your personal information.

Canadian Standards Association (operating as “CSA Group”), under whose auspices this National Standard has been produced, was chartered in 1919 and accredited by the Standards Council of Canada to the National Standards system in 1973. It is a not-for- profit, nonstatutory, voluntary membership association engaged in standards development and certification activities.


CSA Group standards reflect a national consensus of producers and users — including manufacturers, consumers, retailers, unions and professional organizations, and governmental agencies. The standards are used widely by industry and commerce and often adopted by municipal, provincial, and federal governments in their regulations, particularly in the fields of health, safety, building and construction, and the environment.


Individuals, companies, and associations across Canada indicate their support for CSA Group’s standards development by

volunteering their time and skills to Committee work and supporting CSA Group’s objectives through sustaining memberships. The more than 7000 committee volunteers and the 2000 sustaining memberships together form CSA Group’s total membership from which its Directors are chosen. Sustaining memberships represent a major source of income for CSA Group’s standards development activities.


CSA Group offers certification and testing services in support of and as an extension to its standards development activities. To ensure the integrity of its certification process, CSA Group regularly and continually audits and inspects products that bear the

CSA Group Mark.


In addition to its head office and laboratory complex in Toronto, CSA Group has regional branch offices in major centres across Canada and inspection and testing agencies in eight countries. Since 1919, CSA Group has developed the necessary expertise to meet its corporate mission: CSA Group is an independent service

organization whose mission is to provide an open and effective forum for activities facilitating the exchange of goods and services through the use of standards, certification and related services to meet national and international needs.


For further information on CSA Group services, write to CSA Group

178 Rexdale Boulevard Toronto, Ontario, M9W 1R3 Canada

A National Standard of Canada is a standard developed by a Standards Council of Canada (SCC) accredited Standards Development Organization, in compliance with requirements and guidance set out by SCC. More information on National Standards of Canada can be found at www.scc.ca.


SCC is a Crown corporation within the portfolio of Innovation, Science and Economic Development (ISED) Canada. With the goal of enhancing Canada's economic competitiveness and social well- being, SCC leads and facilitates the development and use of national and international standards. SCC also coordinates Canadian participation in standards development, and identifies strategies to advance Canadian standardization efforts.


Accreditation services are provided by SCC to various customers, including product certifiers, testing laboratories, and standards development organizations. A list of SCC programs and accredited bodies is publicly available at www.scc.ca.


Standards Council of Canada 600-55 Metcalfe Street Ottawa, Ontario, K1P 6L5 Canada




Cette Norme Nationale du Canada est disponible en versions française et anglaise.


Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users to judge its suitability for their particular purpose.

®A trademark of the Canadian Standards Association, operating as “CSA Group”

National Standard of Canada


CSA A123.26:21

Performance requirements for climate resilience of low slope membrane roofing systems




®A trademark of the Canadian Standards Association, operating as “CSA Group”




Published in January 2021 by CSA Group A not-for-profit private sector organization

178 Rexdale Boulevard, Toronto, Ontario, Canada M9W 1R3


To purchase standards and related publications, visit our Online Store at www.csagroup.org/store/

or call toll-free 1-800-463-6727 or 416-747-4044.


ICS 91.060.50

ISBN 978-1-4883-3314-9


© 2021 Canadian Standards Association

All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher.


CSA A123.26:21

Performance requirements for climate resilience of low slope

membrane roofing systems


Contents

Technical Committee on Bituminous Roofing Materials 2


Task Group on Climate Resilience of Low Slope Membrane Roofing Systems 6


Preface 8


  1. Scope 9


  2. Reference publications 10


  3. Definitions and abbreviations 11

    1. Definitions 11

    2. Abbreviations 12


  4. Determination of performance level 12


  5. Performance requirements 12


  6. Wind performance requirements 13

    1. Roof 13

    2. Rooftop add-ons 14


  7. Rain performance requirements 15

    1. Rain water resistance 15

    2. Rain water control 17


Annex A (informative) — Commentary on Clauses 6 and 7 19

Annex B (informative) — Guidelines for in-situ negative pressure uplift test on low slope membrane roof systems 23

Annex C (informative) — General guidelines 29


January 2021 © 2021 Canadian Standards Association 1

CSA A123.26:21

Performance requirements for climate resilience of low slope

membrane roofing systems


Preface

This is the first edition of CSA A123.26, Performance requirements for climate resilience of low slope membrane roofing systems.


This Standard was prepared by the Task Group on Climate Resilience of Low Slope Membrane Roofing Systems, under the jurisdiction of the Technical Committee on Bituminous Roofing Materials and the Strategic Steering Committee on Construction and Civil Infrastructure, and has been formally approved by the Technical Committee.

This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Notes:

  1. Use of the singular does not exclude the plural (and vice versa) when the sense allows.

  2. Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose.

  3. This Standard was developed by consensus, which is defined by CSA Policy governing standardization — Code of good practice for standardization as “substantial agreement. Consensus implies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet not be in full agreement with all clauses of this Standard.

  4. To submit a request for interpretation of this Standard, please send the following information to inquiries@csagroup.org and include “Request for interpretation” in the subject line:

    1. define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;

    2. provide an explanation of circumstances surrounding the actual field condition; and

    3. where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue.

      Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and are available on the Current Standards Activities page at standardsactivities.csa.ca.

  5. This Standard is subject to review within five years from the date of publication. Suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquiries@csagroup.org and include “Proposal for change” in the subject line:

    1. Standard designation (number);

    2. relevant clause, table, and/or figure number;

    3. wording of the proposed change; and

    4. rationale for the change.


January 2021 © 2021 Canadian Standards Association 8

CSA A123.26:21

Performance requirements for climate resilience of low slope

membrane roofing systems


CSA A123.26:21

Performance requirements for climate resilience of low slope membrane roofing systems


1 Scope


1.1

This Standard outlines requirements for low slope membrane roofing systems (LSMRS) when identified as “silver” and “gold” performance level based on the climate severity and resilience requirements.

Note: The National Building Code of Canada and the National Energy Code of Canada for Buildings provides “bronze” requirements for LSMRS.


1.2

This Standard is intended to be used by building designers, building owners, building code officials, product manufacturers, and installers.


1.3

The requirements provided in this Standard do not include, nor are they intended to override other requirements, by the governing building code or the authority having jurisdiction (AHJ).


1.4

This Standard does not address the climatic adaptation requirements for the structural support (deck) below the LSMRS.


1.5

This Standard does not purport to address all the health and safety aspects associated with its use. Anyone using this Standard has the responsibility to consult with the appropriate authorities and to establish health and safety practices, in conjunction with any existing applicable regulatory requirements, prior to its use.


1.6

In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.


Notes to tables and figures are considered part of the table or figure and may be written as requirements.


January 2021 © 2021 Canadian Standards Association 9